Reference · 6 min read
How to read an OTDR trace
An OTDR trace plots the light scattered back from the fibre, in dB on the vertical axis, against distance in km on the horizontal axis. Read it from left to right: a spike at the launch connector, a straight line sloping down along the fibre, small steps down at splices, spikes at connectors, and finally a large spike where the fibre ends, after which the trace falls into noise. Each of those features is an event in the file’s event table.
You can open any .sor file in the free OTDR trace viewer to follow along. The trace below is a real one, from the EXFO FTB-4 sample at 1310 nm.
- 1310 nm
- 10 ns pulse
- IOR 1.4677
- 3.63 km
| # | km | Type | Loss | Refl. |
|---|---|---|---|---|
| 1 | 0.000 | Reflective | 0.20 | -49.25 |
| 2 | 0.478 | Gainer | -0.34 | — |
| 3 | 0.578 | Non-reflective | 0.11 | — |
| 4 | 0.779 | Non-reflective | 0.34 | — |
| 5 | 0.873 | Non-reflective | 0.06 | — |
| 6 | 1.155 | Non-reflective | 0.10 | — |
| 7 | 1.249 | Non-reflective | 0.06 | — |
| 8 | 1.448 | Reflective | 0.51 | -50.62 |
| 9 | 3.629 | Fibre end | — | -15.74 |
Distance in km from the launch point. Loss and reflectance in dB.
- Total loss
- 2.22 dB
- ORL
- 36.0 dB
- Events
- 9
The two axes
- Distance (km) is worked out from the time the light takes to come back and the fibre’s group index; how OTDR distance is calculated shows the steps.
- Power (dB) is relative, not an absolute level. OTDRs show one-way loss, so a drop of 1 dB on the trace is 1 dB of loss in the fibre, even though the light travelled there and back.
Only differences on the vertical axis matter: the drop across an event is its loss, and the drop per kilometre along a clean section is the attenuation.
The launch and the dead zone
The trace starts with a reflection from the OTDR’s own connector or the launch cable. In the sample it is event 1, at 0.0000 km with a reflectance of -49.25 dB. Right after it the detector is still recovering from that reflection, so the first few metres cannot be measured. This is the dead zone, and it is why acceptance tests use a launch cable: it moves the first connector you care about out of the dead zone.
Fibre sections: the slope
Between events the trace is a straight line falling at a steady rate. That slope is the fibre’s attenuation in dB/km. Standard single-mode fibre is typically around 0.33 to 0.35 dB/km at 1310 nm and about 0.19 to 0.20 dB/km at 1550 nm. A section that slopes more steeply than its neighbours points to fibre that is stressed along its length, or to a different fibre type.
A short section gives an unreliable slope, because a few metres of noise move the fit. OTDR Wizard only reports attenuation for sections of at least 500 m for this reason.
Splices and bends: steps down
A fusion splice or a bend shows as a small step down with no spike. These are non-reflective events. In the sample, event 4 at 0.7786 km loses 0.34 dB, and events 5 to 7 lose under 0.1 dB each, which is typical for good fusion splices.
To tell a splice from a bend, compare the same event at 1310 and 1550 nm. A splice loses about the same at both. A bend loses noticeably more at 1550 nm, because the longer wavelength escapes a curved fibre more easily. In the sample pair, event 4 loses 0.34 dB at 1310 nm and 0.38 dB at 1550 nm: close enough to be a splice. Opening both files together in the viewer draws them on one chart, which makes this comparison quick.
Gainers: a step up
Sometimes a splice shows a step up, as if the fibre gained light. Event 2 of the sample does this, with a loss of -0.34 dB. A gainer happens when the two fibres joined have different backscatter, usually because their mode-field diameters differ: the OTDR sees more light coming back after the splice and reads it as a gain. The real loss is positive; measuring from both ends and averaging the two readings gives it. A gainer from one direction is a loss from the other.
Connectors: spikes
A connector, a mechanical splice or any glass-to-air gap reflects light, so it shows as a spike, usually followed by a small step down. These are reflective events. Event 8 of the sample, at 1.4477 km, is a connector pair: it loses 0.51 dB with a reflectance of -50.62 dB.
Reflectance is the height of the reflection, as a negative number: −55 dB is a small reflection, −35 dB a large one. Dirty or damaged connectors reflect more and lose more. The event table guide explains how loss and reflectance are listed for each event, and pass/fail limits covers the usual thresholds.
The fibre end
At the far end the light leaves the glass. A cleaved or connectorised end reflects strongly, so the trace shows a tall spike and then drops into noise. In the sample the end is event 9 at 3.6286 km, with a reflectance of -15.74 dB. A broken or crushed fibre often has no spike at all: the trace simply falls away.
The distance to that last event is the fibre’s length. If the length is much shorter than expected and the end is non-reflective, look for a break.
Ghosts: echoes past the end
A strong reflection can bounce back and forth inside the fibre and show up a second time further along the trace. These echoes are called ghosts. They have no loss, they often appear beyond the fibre end, and they sit at a whole multiple of the distance to the reflection that caused them.
The EXFO MaxTester sample shows this. Its fibre ends at 3.7392 km, yet the file lists more reflective events at 3.9125, 7.3275 and 7.5018 km. The last one is close to twice the fibre length, where an echo of the end reflection would land. Anything listed after the fibre end is not part of the fibre and should be left out of the results.
Noise and range
After the fibre end the trace is noise: a rough band near the bottom of the chart. How far down that noise sits depends on the pulse width and the averaging time. A wider pulse reaches further but blurs events that are close together; a narrow pulse separates them but the trace becomes noisy sooner. That is why the same fibre can look different on two files taken with different settings. The SOR file parameters page lists every setting stored in the file.
A quick reading routine
- Check the length: the distance to the fibre end should match the cable record.
- Check the total loss against your loss budget.
- Look at each step and spike in turn and compare its loss and reflectance with your limits.
- Look for gainers, and compare with a test from the other end if you have one.
- Ignore anything after the fibre end, and treat regularly spaced spikes beyond it as ghosts.
- For bends, compare 1310 and 1550 nm on the same chart.
The OTDR glossary defines the terms used on traces and in reports.